DIP SWITCH SETTINGS
For conversion Thayer's Quest machines.
Time per Coin
A1 | A2 | A3 | Time |
Off | Off | Off | 110 Seconds |
On | Off | Off | 95 Seconds |
Off | On | Off | 80 Seconds |
On | On | Off | 70 Seconds |
Off | Off | On | 60 Seconds |
On | Off | On | 45 Seconds |
Off | On | On | 30 Seconds |
On | On | On | Free Play |
Number of Coins Required for one Credit
A4 | # of coins |
Off |
1 coin per game |
On | 2 coins per game |
Number of lives per game
A5 | Lives |
Off | 3 lives |
On | 5 lives |
Attract Mode
A6 | Mode |
Off | Attract mode audio enabled per setting of A7 |
On | Attract mode audio muted |
A7 | Mode |
Off | Attract mode audio always on |
On | Attract mode audio plays only one out of eight times |
Diagnostics
B1 | Mode |
Off | Normal game play mode |
On | Self diagnostics mode |
Laserdisc Player
B4 | LD Player |
Off | Pioneer LD-V1000 |
On | Pioneer PR-7820 |
B5 | LD Player |
Off | Pioneer LD-V1000 |
On | Pioneer PR-7820 |
Note: B4 and B5 must BOTH be On or Off
Not Used - A8, B2, B3, B6, B7, B8
Manufacturer suggested switch settings are indicated by Bold Print
HOME
| LASER GAMES |
LASER COMMUNITY
| TECH CENTER
Questions? Comments? Problems? CONTACT US
dragons-lair-project.com was created by Jeff Kinder & Dave Hallock, 1997 - 2024.